Table 2-1. Technical Specifications of Co-Generation Steam Turbine
 

Designation

Item (Unit)

6 MW 6 M

Back-press. Back-press

6 MW Single extract.

6 MW Single extract.

12 MW

Back-press.

12 MW Single extract.

Model

B6-3.43/0.49

C6-4.9/0.49

C6-4.9/0.981

B12-8.83/4.02

C12-4.9/0.49

Rated output KW

6000

6000

6000

12000

12000

Max. output KW Max. output K  

6000

6000

13473

12000

Speed r/min

3000

3000

3000

3000

3000

Steam pres. before stop valve MPa (abs)

3.432

4.9

4.9

8.826

4.9

Steam temp. before stop valve

435

435

435

535

470

Rated/Max. steam flow t/h

65.41

44/50.3

50.33/70.66

253.8/280

79.7/107.2

Extract steam pres. for process MPa(abs)  

0.49

0.981

4.02

0.49

Rated/Max. extract. steam for process t/h  

25/35

30/50

245/259

50/70

Extract steam pres. for heat supply MPa(abs)

Exhau.Pres.0.49

       
Rated/Max. extract. steam for heating t/h          

 

 Table 2-2. Technical Specifications of Co-Generation Steam Turbine
 

 Designation

Item (Unit)

12 MW Single extract.

12 MW

Double extract.

12 MW

Double extract.

25 MW Single extract.

25 MW

Single extract.

Model 

C12-4.9/0.981

CC12-4.9/0.981/0.49

CC12-3.43/0.98/0.118

C25-8.83/0.118

C25-8.83/0.98

Rated output KW

12000

12000

12000

25000

25000

Max. Output KW Max. Output K

12000

15000

14000

30000

30000

Speed r/min

3000

3000

3000

3000

3000

Steam pres. before stop valve MPa (abs)

4.9

4.9

3.432

8.826

8.826

Steam temp. before stop valve

470

470

450

535

535

Rated/Max. steam flow t/h

87.94/109.1

100.5/117.5

114/128

125/168

169/211

Extract steam pres. for process MPa(abs)

0.981

0.981

0.98

 

0.98

Rated/Max. extract steam for process t/h

50/80

25/70

50/80

 

110/130

Extract. steam pres. for heat supply MPa(abs)  

0.49

0.118

0.118

 
Rated/Max. extract steam for heating t/h  

40/70

40/60

85/115

 

 

Table 2-3. Technical Specifications of Co-Generation Steam Turbine
 

 Designation

Item (Unit)

25 MW

Double extract.

25 MW

Double extract.

50 MW Single extract.

50 MW Single extract.

50 MW

Double extract.

Model

CC25-8.83/0.98/0.118

CC25-8.83/1.28/0.118

C50-8.83/0.118

C50-8.83/1.28

CC50-8.83/0.98/0.118

Rated output KW

25000

25000

50000

50000

50000

Max. output KW Max. output K

30000

30000

60000

60000

60000

Speed r/min

3000

3000

3000

3000

3000

Steam pres. before stop valve MPa (abs)

8.826

8.826

8.826

8.826

8.826

Steam temp. Before stop valve

535

535

535

535

535

Rated/Max. Steam flow t/h

153 / 210

155.25 / 196.7

235 / 291

341 / 396.8

299 / 358

Extract steam pres. for process MPa(abs)

0.98

1.275

 

1.28

0.98

Rated/Max. Extract. steam for process t/h

60 / 100

60 / 100

 

200 / 230

125 / 200

Extract steam pres. for heat supply MPa(abs)

0.118

0.118

0.118

 

0.118

Rated/Max. Extract. steam for heating t/h

46 / 90

40 / 90

160 / 200

 

90 / 150

 

Table 2-4. Technical Specifications of Co-Generation Steam Turbine
 

  Designation

Item (Unit)

50 MW

Double extract.

100 MW Single extract.

100 MW

Double extract.

200 MW

Single extract.

200 MW Double extract.

Model  CC50-8.83/1.28/0.118 C100-8.83/0.981

CC100-8.83/1.27/0.118

C145/200-12.7/535/535

CC140/200-12.7/535/535

Rated output KW

50000

100000

100000

145000 / 200000

140000 / 200000

Max. Output KW Max. Output K

60000

125000

125000

219200

217900

Speed r/min

3000

3000

3000

3000

3000

Steam pres. before stop valve MPa (abs)

8.826

8.83

8.83

12.748

12.748

Steam temp. before stop valve

535

535

535

535

535

Rated/Max. steam flow t/h

321/ 416

444 / 565

566 / 708

610 / 670

610 / 670

Extract steam pres. for process MPa(abs)

1.28

0.981

1.27

 

1.0787

Rated/Max. extract steam for process t/h

140 / 230

100 / 135

200 / 350

 

50 / 50

Extract. steam pres. for heat supply MPa(abs)

0.118

 

0.118

0.2452

0.2452

Rated/Max. extract steam for heating t/h

100 / 160

 

150 / 250

405 / 450

350 / 390

 

Remark: The selection of boiler / generator matching with turbine may be made with reference to Table 1.